Evaporative air conditioner project

- Oct 23, 2019-

Directly send air cooling form on the front of the unit wall (upper/outer wind)

The evaporative air-conditioner is installed on the front of the factory wall. Each main engine is an independent air supply system. The unit sends air through the air supply duct, and then the special electric louver air outlet or manual louver air outlet, the cold air is evenly distributed from the front direction, and the air is sent into the room. At each position, cool down and adjust the internal air of the production plant.

Unit air outlet → air supply supervisor → wall front manual or electric blind air outlet → production position

Vertical air supply cooling on the roof of the unit

Evaporative air-conditioner is installed on the factory floor. Each main engine is an independent air supply system. The unit sends air through the air supply duct, and then passes the special air outlet or manual louver air outlet to make the cold air vertical from top to bottom. The location, cooling and adjustment to replace the hot air inside the production position, in order to achieve the overall cooling and cooling effect of the plant.

Unit air outlet → air supply supervisor → mushroom head air outlet or manual louver air outlet → production position


Unit front air duct parallel air supply cooling

The evaporative air conditioner is installed in the building or indoor computer room. Each main engine is an independent air supply system. The unit discharges air through the main air supply duct (or through the air duct), and passes through the special louver air outlet or manual louver air outlet or diffuse flow. The cold air is sent vertically from top to bottom, and is pressed into the indoor operating position to cool down and adjust the hot air inside the production to achieve the overall cooling and cooling effect of the plant.

Unit air outlet → air supply main pipe → air supply branch pipe → air duct manual louver air outlet → production position

640.webp

The unit is directly on the front of the duct and the local air supply is cooled.

The evaporative air-conditioner is installed in a building or indoor computer room. Each main engine is an independent air supply system. The unit sends air through the main air supply duct (or the air duct is sent through the ground), and the special louver air outlet or manual louver air outlet. The cold air is sent vertically from the bottom to the indoor operating position to cool down and adjust the hot air inside the production position to achieve the effect of partial cooling and cooling of the plant.

Air outlet of the unit → main air supply duct → ground support air duct → manual louver air outlet → production position.

640.webp (1)